DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
L-8 CERP Floridan Exploratory WellPBF-15863899874382

Start Test Date:22-FEB-2007 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):13240
Discharge Rate (gal/min):125Horizontal K (ft/day):441.33
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):1910Storativity:
Tested Interval Max. (ft BLS):1940Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):6.62
SourceReferenceCitation Id
SOUTH FLORIDA WMD ANDERSON, STEVEN. SEPT. 2008. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM L-8 (PBF-15) PALM BEACH COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-25214
Comments:PACKER TEST 1 PARAMETERS ARE FOR THE MAXIMUM RATE OF IS MAXIMUM OF 4 STEP SPECIFIC CAPACITY TESTING. (STEPS 50,75,100 & 125 GPM)



SitePumped WellX-Coord(ft)Y-Coord (ft)
L-8 CERP Floridan Exploratory WellPBF-15863899874382

Start Test Date:26-FEB-2007 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):10540
Discharge Rate (gal/min):125Horizontal K (ft/day):351.33
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):1700Storativity:
Tested Interval Max. (ft BLS):1730Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):5.27
SourceReferenceCitation Id
SOUTH FLORIDA WMD ANDERSON, STEVEN. SEPT. 2008. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM L-8 (PBF-15) PALM BEACH COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-25214
Comments:PACKER TEST 2 PARAMETERS ARE FOR THE MAXIMUM RATE OF IS MAXIMUM OF 4 STEP SPECIFIC CAPACITY TESTING. (STEPS 50,75,100 & 125 GPM)



SitePumped WellX-Coord(ft)Y-Coord (ft)
L-8 CERP Floridan Exploratory WellPBF-15863899874382

Start Test Date:27-FEB-2007 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):10180
Discharge Rate (gal/min):125Horizontal K (ft/day):339.33
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):1560Storativity:
Tested Interval Max. (ft BLS):1590Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):5.09
SourceReferenceCitation Id
SOUTH FLORIDA WMD ANDERSON, STEVEN. SEPT. 2008. HYDROGEOLOGIC INVESTIGATION OF THE FLORIDAN AQUIFER SYSTEM L-8 (PBF-15) PALM BEACH COUNTY, FL. SFWMD TECHNICAL PUBLICATION WS-25214
Comments:PACKER TEST 3 PARAMETERS ARE FOR THE MAXIMUM RATE OF IS MAXIMUM OF 4 STEP SPECIFIC CAPACITY TESTING. (STEPS 50,75,100 & 125 GPM)

Page generated at: 28-SEP-2024 18:21 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?