Start Test Date: | 01-JAN-2001 0000 | Aquifer: | UPPER FLORIDAN AQUIFER (UFA) |
Test Type: | APT | Transmissivity (ft2/day): | 32620 |
Discharge Rate (gal/min): | 385 | Horizontal K (ft/day): | |
Hours Pumped: | 72 | Vertical K (ft/day): | |
Tested Interval Min. (ft BLS): | 100 | Storativity: | .00042 |
Tested Interval Max. (ft BLS): | 150 | Leakance (1/day): | .04 |
No. Monitored Wells: | | Specific Capacity (gpm/ft): | |