DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
City of Pinellas Park Upper Zone APINPAR_T-1953791287799

Start Test Date:01-JAN-2001 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):32620
Discharge Rate (gal/min):385Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):100Storativity:.00042
Tested Interval Max. (ft BLS):150Leakance (1/day):.04
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
 
Comments:Upper & lower zones also monitored; drawdown & recovery data analyzed using Cooper & Jacob methods.