DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Plantation RO Test Well 2
PLARO2PW
213498
997587
Start Test Date:
01-JAN-1982 0000
Aquifer:
INTERMEDIATE AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
5510
Discharge Rate (gal/min):
819
Horizontal K (ft/day):
Hours Pumped:
72.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
243
Storativity:
.00031
Tested Interval Max. (ft BLS):
380
Leakance (1/day):
.00026
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Post, Buckley, Schuh & Jernigan, 1982(b), p. 3-3,3-5, Tabls 3-1 & 4-3, Fig. 3-1 & C-1, App. A; Hutchinson, 1992. p. 14,20.
Comments:
Hydraulic parameters represent log. avgs.of 4 analytical methods used fro drawdown & recovery; data corrections were made to account for barometric & tidal effects; upper zones were also monitored.: DATE = REPORT YEAR