DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF PLANTATION CENTRAL WTF R.O. REJECT DISPOSAL SYSTEM
PLT-ROI1
896121
652840
Start Test Date:
17-APR-1990 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1897
Discharge Rate (gal/min):
Horizontal K (ft/day):
12.65
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2150
Storativity:
Tested Interval Max. (ft BLS):
2300
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CDM, NOVEMBER 1990, CITY OF PLANTATION CENTRAL DISTRICT WTF R.O. DISPOSAL WELL NO. 1, WELL COMPLETION REPORT
Comments:
STRADDLE PACKER TEST COMPLETED FOR WATER QUALITY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF PLANTATION CENTRAL WTF R.O. REJECT DISPOSAL SYSTEM
PLT-ROI1
896121
652840
Start Test Date:
18-APR-1990 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
1897
Discharge Rate (gal/min):
Horizontal K (ft/day):
27.1
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1920
Storativity:
Tested Interval Max. (ft BLS):
1990
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CDM, NOVEMBER 1990, CITY OF PLANTATION CENTRAL DISTRICT WTF R.O. DISPOSAL WELL NO. 1, WELL COMPLETION REPORT
Comments:
STRADDLE PACKER TEST FOR WATER QUALITY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF PLANTATION CENTRAL WTF R.O. REJECT DISPOSAL SYSTEM
PLT-ROI1
896121
652840
Start Test Date:
19-APR-1990 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
813
Discharge Rate (gal/min):
Horizontal K (ft/day):
11.61
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1800
Storativity:
Tested Interval Max. (ft BLS):
1870
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CDM, NOVEMBER 1990, CITY OF PLANTATION CENTRAL DISTRICT WTF R.O. DISPOSAL WELL NO. 1, WELL COMPLETION REPORT
Comments:
STRADDLE PACKER TEST CONDUCTED FOR WATER QUALITY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF PLANTATION CENTRAL WTF R.O. REJECT DISPOSAL SYSTEM
PLT-ROI1
896121
652840
Start Test Date:
20-APR-1990 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
2710
Discharge Rate (gal/min):
Horizontal K (ft/day):
38.71
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1583
Storativity:
Tested Interval Max. (ft BLS):
1653
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CDM, NOVEMBER 1990, CITY OF PLANTATION CENTRAL DISTRICT WTF R.O. DISPOSAL WELL NO. 1, WELL COMPLETION REPORT
Comments:
CAUTION: ACCURATE ESTIMATE OF TRANSMISSIVITY NOT AVAILABLE DUE TO CHANGING WATER QUALITY DURING DRAWDOWN AND NEAR INSTANTANEOUS RECOVERY. THIS VALUE IS BASED ON LITHO SAMPLES AND GEOPHYSICAL LOGS!!!!!
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CITY OF PLANTATION CENTRAL WTF R.O. REJECT DISPOSAL SYSTEM
PLT-ROI1
896121
652840
Start Test Date:
17-MAY-1990 0000
Aquifer:
LOWER FLORIDAN AQUIFER (FZ2)
Test Type:
PACKER
Transmissivity (ft2/day):
2439
Discharge Rate (gal/min):
Horizontal K (ft/day):
243.9
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2645
Storativity:
Tested Interval Max. (ft BLS):
2655
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CDM, NOVEMBER 1990, CITY OF PLANTATION CENTRAL DISTRICT WTF R.O. DISPOSAL WELL NO. 1, WELL COMPLETION REPORT
Comments:
STRADDLE PACKER TEST CONDUCTED WITHIN CONFINING SEQUENCE BETWEEN UFA AND BOULDER ZONE
Page generated at: 04-OCT-2025 08:25 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?