DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
RIVER RANCHPOF-265966381241328

Start Test Date:21-JUL-2008 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):12170
Discharge Rate (gal/min):795Horizontal K (ft/day):81
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):248Storativity:.00005
Tested Interval Max. (ft BLS):320Leakance (1/day):.007
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD ANDERSON, 2011. SFWMD TECHNICAL PUBLICATOIN WS-29339
Comments:HANTUSH (1960 ) ANALYTICAL SOLUTION PRESENTED. 1 FAS MONITOR WELL WITH 2 SAS MONITOR WELLS. LEAKANCE IS BELIEVED TO BE FROM OVERLYING INTERMEDIATE CONFINING UNIT.

Page generated at: 04-OCT-2025 10:14 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?