DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PORT ST LUCIE RO WELLFIELD AT THE PRINEVILLE WTP
PSL-RO1
869491
1081566
Start Test Date:
01-JUL-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
51768
Discharge Rate (gal/min):
1467
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
650
Storativity:
.00058
Tested Interval Max. (ft BLS):
1350
Leakance (1/day):
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
HARTMAN & ASSOC., CITY OF PORT ST LUCIE WATER USE PERMIT APPLICATION, SEPT 2003
Comments:
THE PORT ST LUCIE WELLFIELD IS OPEN TO BOTH THE UPPER FLORIDAN AND MIDDLE FLORIDAN (OFTEN CALLED THE FIRST FLOW ZONE OF THE LOWER FLORIDAN) AQUIFERS. THE CONSULTANT ASSUMED A 70:30 SPLIT OF TRANSMISSIVITY (UPPER:LOWER), BUT DID NOT PROVIDE EXPLANATION FOR THAT ASSUMPTION.