DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:24-JAN-2003 1148Aquifer:BOULDER ZONE
Test Type:OTHERTransmissivity (ft2/day):281250
Discharge Rate (gal/min):8604Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2764Storativity:
Tested Interval Max. (ft BLS):3350Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM SPECIFIC CAPACITY DURING INJECTION TEST



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:19-JUN-2002 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):24.7
Discharge Rate (gal/min):9.6Horizontal K (ft/day):.68
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2319Storativity:
Tested Interval Max. (ft BLS):2350Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM DRAWDOWN.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:22-JUN-2002 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):12737
Discharge Rate (gal/min):81.1Horizontal K (ft/day):121.89
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2160Storativity:
Tested Interval Max. (ft BLS):2264Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:25-JUN-2002 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):1.46
Discharge Rate (gal/min):.8Horizontal K (ft/day):.085
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1920Storativity:
Tested Interval Max. (ft BLS):1936Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM DRAWDOWN.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:29-JUN-2002 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2618
Discharge Rate (gal/min):82.7Horizontal K (ft/day):157.04
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1520Storativity:
Tested Interval Max. (ft BLS):1536Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:29-JUN-2002 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2.81
Discharge Rate (gal/min):1.9Horizontal K (ft/day):.17
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1760Storativity:
Tested Interval Max. (ft BLS):1776Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS PAPADOPULOS-COOPER, 1967 - FROM DRAWDOWN.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:04-JUL-2002 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):6.94
Discharge Rate (gal/min):4.2Horizontal K (ft/day):.42
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1552Storativity:
Tested Interval Max. (ft BLS):1568Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:29-AUG-2002 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):16.6
Discharge Rate (gal/min):7.3Horizontal K (ft/day):.34
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1859.2Storativity:
Tested Interval Max. (ft BLS):1906.9Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:04-OCT-2002 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):5637
Discharge Rate (gal/min):81.4Horizontal K (ft/day):119.34
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2766Storativity:
Tested Interval Max. (ft BLS):2812.5Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:06-OCT-2002 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):5.32
Discharge Rate (gal/min):3Horizontal K (ft/day):.26
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2744.9Storativity:
Tested Interval Max. (ft BLS):2764.7Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:08-OCT-2002 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):44.5
Discharge Rate (gal/min):19.9Horizontal K (ft/day):2.2
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2361.9Storativity:
Tested Interval Max. (ft BLS):2381.7Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY



SitePumped WellX-Coord(ft)Y-Coord (ft)
PORT ST. LUCIE LTC WATER TREATMENT PLANTPSLLTC-IW18506111104259

Start Test Date:09-OCT-2002 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):105.1
Discharge Rate (gal/min):33.7Horizontal K (ft/day):.94
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2426.9Storativity:
Tested Interval Max. (ft BLS):2536.7Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARCADIS. 2003. OPERATIONAL TESTING REQUEST. CITY OF PORT ST. LUCIE CLASS I INJECTION WELL SYSTEM.
Comments:ANALYSIS METHOD IS TURCAN, 1963 - FROM RECOVERY