DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ACME IMPROVEMENT DIST WWTP
PW-18
910942
827277
Start Test Date:
24-SEP-1980 0000
Aquifer:
SURFICIAL AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
5964
Discharge Rate (gal/min):
900
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
70
Storativity:
.0054
Tested Interval Max. (ft BLS):
90
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GEE & JENSON, WATER USE PERMIT APPLICATION AND SUPPLEMENTARY ENGINEERING REPORT FOR ACME IMPROVEMENT DIST., DEC. 8, 1980
Comments:
PARTIAL PENETRATION AND CANAL LEAKANCE NOT ACCOUNTED FOR. RECOMMENDED T IS AVERAGE OF EARLY TIME RESULTS.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
18-2D
910942
827277
BOULTON
130
6566
.00025
18-3D
910942
827277
BOULTON
200
6566
.000011
Page generated at: 04-OCT-2025 06:59 EDT