DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ACME IMPROVEMENT DIST WWTPPW-18910942827277

Start Test Date:24-SEP-1980 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):5964
Discharge Rate (gal/min):900Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):70Storativity:.0054
Tested Interval Max. (ft BLS):90Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GEE & JENSON, WATER USE PERMIT APPLICATION AND SUPPLEMENTARY ENGINEERING REPORT FOR ACME IMPROVEMENT DIST., DEC. 8, 1980
Comments:PARTIAL PENETRATION AND CANAL LEAKANCE NOT ACCOUNTED FOR. RECOMMENDED T IS AVERAGE OF EARLY TIME RESULTS.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
18-2D
910942
827277
BOULTON
130
6566
.00025
18-3D
910942
827277
BOULTON
200
6566
.000011

Page generated at: 04-OCT-2025 06:59 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?