SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:10-APR-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):104.9
Discharge Rate (gal/min):32.4Horizontal K (ft/day):35.2
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1185Storativity:.0001
Tested Interval Max. (ft BLS):1207Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 3.45 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:10-APR-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):116.9
Discharge Rate (gal/min):90Horizontal K (ft/day):39.2
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1185Storativity:.0001
Tested Interval Max. (ft BLS):1207Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 3.82 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:10-APR-1996 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):118.6
Discharge Rate (gal/min):105Horizontal K (ft/day):39.8
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1185Storativity:.0001
Tested Interval Max. (ft BLS):1207Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 3.87 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:25-APR-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.18
Discharge Rate (gal/min):1.3Horizontal K (ft/day):.08
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1603Storativity:.0001
Tested Interval Max. (ft BLS):1620Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.009 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:25-APR-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.28
Discharge Rate (gal/min):3Horizontal K (ft/day):.12
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1603Storativity:.0001
Tested Interval Max. (ft BLS):1620Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.014 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:29-APR-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):1.17
Discharge Rate (gal/min):4Horizontal K (ft/day):.41
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1739Storativity:.0001
Tested Interval Max. (ft BLS):1760Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.05 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:29-APR-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):2.48
Discharge Rate (gal/min):8.3Horizontal K (ft/day):.87
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1739Storativity:.0001
Tested Interval Max. (ft BLS):1760Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.10 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:29-APR-1996 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):4.13
Discharge Rate (gal/min):10.7Horizontal K (ft/day):1.45
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1739Storativity:.0001
Tested Interval Max. (ft BLS):1760Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.16 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:02-MAY-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.25
Discharge Rate (gal/min):1.5Horizontal K (ft/day):.08
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1895Storativity:.0001
Tested Interval Max. (ft BLS):1918Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = .012 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:02-MAY-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.25
Discharge Rate (gal/min):1.8Horizontal K (ft/day):.08
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1895Storativity:.0001
Tested Interval Max. (ft BLS):1918Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.012 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:02-MAY-1996 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.25
Discharge Rate (gal/min):2.5Horizontal K (ft/day):.08
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1895Storativity:.0001
Tested Interval Max. (ft BLS):1918Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.012 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-MAY-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.73
Discharge Rate (gal/min):2Horizontal K (ft/day):.27
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2100Storativity:.0001
Tested Interval Max. (ft BLS):2120Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.038 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-MAY-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.84
Discharge Rate (gal/min):6Horizontal K (ft/day):.31
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2100Storativity:.0001
Tested Interval Max. (ft BLS):2120Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.039 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-MAY-1996 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.73
Discharge Rate (gal/min):8Horizontal K (ft/day):.27
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2100Storativity:.0001
Tested Interval Max. (ft BLS):2120Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.037 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:13-MAY-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.21
Discharge Rate (gal/min):1.25Horizontal K (ft/day):.07
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2298Storativity:.0001
Tested Interval Max. (ft BLS):2320Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.011 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:13-MAY-1996 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.63
Discharge Rate (gal/min):5Horizontal K (ft/day):.21
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2298Storativity:.0001
Tested Interval Max. (ft BLS):2320Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.032 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:13-MAY-1996 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):.72
Discharge Rate (gal/min):7Horizontal K (ft/day):.24
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2298Storativity:.0001
Tested Interval Max. (ft BLS):2320Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 0.037 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-APR-1998 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):140.2
Discharge Rate (gal/min):33Horizontal K (ft/day):43.1
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:.0001
Tested Interval Max. (ft BLS):1054Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 4.25 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-APR-1998 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):118
Discharge Rate (gal/min):30Horizontal K (ft/day):36.3
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:.0001
Tested Interval Max. (ft BLS):1054Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 4.08 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-APR-1998 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):128.5
Discharge Rate (gal/min):60Horizontal K (ft/day):39.5
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:.0001
Tested Interval Max. (ft BLS):1054Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 4.41 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FASSCRWWTPIW1418933641113

Start Test Date:08-APR-1998 0300Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):128.5
Discharge Rate (gal/min):100Horizontal K (ft/day):39.5
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:.0001
Tested Interval Max. (ft BLS):1054Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:SPECIFIC CAPACITY = 3.88 GPM/FT