DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
21-MAY-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
67.3
Discharge Rate (gal/min):
13.5
Horizontal K (ft/day):
27.6
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
892
Storativity:
.0001
Tested Interval Max. (ft BLS):
910
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 2.23 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
21-MAY-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
73.7
Discharge Rate (gal/min):
48.6
Horizontal K (ft/day):
30.2
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
892
Storativity:
.0001
Tested Interval Max. (ft BLS):
910
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 2.42 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
21-MAY-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
71.2
Discharge Rate (gal/min):
76.1
Horizontal K (ft/day):
29.2
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
892
Storativity:
.0001
Tested Interval Max. (ft BLS):
910
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 2.35 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
04-JUN-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.09
Discharge Rate (gal/min):
5
Horizontal K (ft/day):
.28
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1895
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.09 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
04-JUN-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.09
Discharge Rate (gal/min):
10
Horizontal K (ft/day):
.28
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1895
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.09 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
05-JUN-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.88
Discharge Rate (gal/min):
5
Horizontal K (ft/day):
.25
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1865
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.12 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
05-JUN-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.88
Discharge Rate (gal/min):
9.2
Horizontal K (ft/day):
.25
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1865
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.12 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
05-JUN-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1.84
Discharge Rate (gal/min):
15
Horizontal K (ft/day):
.16
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1865
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.08 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPMW1
418783
641074
Start Test Date:
05-JUN-1996 0300
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.65
Discharge Rate (gal/min):
10
Horizontal K (ft/day):
.23
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1865
Storativity:
.0001
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.11 GPM/FT
Page generated at: 28-SEP-2024 19:33 EDT
DBHYDRO Menu
|