DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SebringSEBRING5128951154096

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):26737
Discharge Rate (gal/min):Horizontal K (ft/day):26
Hours Pumped:12Vertical K (ft/day):
Tested Interval Min. (ft BLS):520Storativity:.00033
Tested Interval Max. (ft BLS):1400Leakance (1/day):.000036
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Geraghty and Miller, 1980(d).
Comments:Test interrupted for two minutes after pumping for 110 minutes; no recovery data collected; not adjusted for barometric or regional trends.:Tested Formation -Oc-AP-AP

Page generated at: 28-SEP-2024 20:18 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?