DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Sebring
SEBRING
512895
1154096
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
26737
Discharge Rate (gal/min):
Horizontal K (ft/day):
26
Hours Pumped:
12
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
520
Storativity:
.00033
Tested Interval Max. (ft BLS):
1400
Leakance (1/day):
.000036
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Geraghty and Miller, 1980(d).
Comments:
Test interrupted for two minutes after pumping for 110 minutes; no recovery data collected; not adjusted for barometric or regional trends.:Tested Formation -Oc-AP-AP
Page generated at: 28-SEP-2024 20:18 EDT