DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Section 21 Wellfield 21-5
SEC21-5
169661
1382041
Start Test Date:
01-JAN-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
67700
Discharge Rate (gal/min):
2695
Horizontal K (ft/day):
Hours Pumped:
240
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
197
Storativity:
.00084
Tested Interval Max. (ft BLS):
663
Leakance (1/day):
.000056
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
Comments:
Drawdown and Recovery monitored at five wells; data corrected for regional trends; analysis performed using Cooper-Jacob, Theis, Hantush-Jacob and Theis (Recovery).