DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Section 21 Wellfield 21-5SEC21-51696611382041

Start Test Date:01-JAN-2005 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):67700
Discharge Rate (gal/min):2695Horizontal K (ft/day):
Hours Pumped:240Vertical K (ft/day):
Tested Interval Min. (ft BLS):197Storativity:.00084
Tested Interval Max. (ft BLS):663Leakance (1/day):.000056
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
 
Comments:Drawdown and Recovery monitored at five wells; data corrected for regional trends; analysis performed using Cooper-Jacob, Theis, Hantush-Jacob and Theis (Recovery).

Page generated at: 10-NOV-2024 16:16 EDT