DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ST LUCIE NUCLEAR POWER PLANTSLNPP-PW9016901096533

Start Test Date:05-MAY-2006 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):6000
Discharge Rate (gal/min):300Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):20Storativity:.002
Tested Interval Max. (ft BLS):60Leakance (1/day):
No. Monitored Wells:12Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GZA GEOENVIRONMENTAL CORP., 2006, EVALUATION OF GROUNDWATER PUMPING TEST DATA INDEPENDENT SPENT FUEL STORAGE INSTALLATION ST LUCIE NUCLEAR POWER PLANT
Comments:DRAWDOWN ANALYSIS: COOPER-JACOBS METHODS VIA AQTESOLVE SOFTWARE

Page generated at: 28-SEP-2024 19:19 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?