DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Southwest St. Pete Well A3
SSTPETE_A3
112500
1234003
Start Test Date:
25-DEC-2001 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
1203209
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
913
Storativity:
.00033
Tested Interval Max. (ft BLS):
1113
Leakance (1/day):
.000029
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Hickey and Spechler, 1979; Hickey, 1982.
Comments:
Hydraulic properties, T, L and S, were estimated from test results using the Hantush_Jacob type curve method; S value compares favorably to storativity calculated from the average rock compressibility data of core samples.:Tested Formation -AP