DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Verna Wellfield Well 3A Site 12b
VER12BPW
231158
1109168
Start Test Date:
01-JAN-1985 0100
Aquifer:
SANDSTONE AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
735
Discharge Rate (gal/min):
195
Horizontal K (ft/day):
Hours Pumped:
48
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
100
Storativity:
.00015
Tested Interval Max. (ft BLS):
106
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Wolansky & Corral, 1985. p. 32-33,104-106.
Comments:
Test duration incl. recovery; no data corrections applied; moderate water-level changes; partial penetration by OB & test wells; OB well far enough away from test well to avoid need for vert. flow correction.: DATE = REPORT YEAR
Page generated at: 04-OCT-2025 10:16 EDT