DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SJRWMD TP SJ93-1: AT STATION VL53-PW, APT SITE VL53VL53-PW6228551700242

Start Test Date:08-MAY-1991 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):7656
Discharge Rate (gal/min):800Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):Storativity:.00027
Tested Interval Max. (ft BLS):200Leakance (1/day):.00023
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
ST. JOHNS RIVER WMD Data compiled in SJRWMD TP SJ93-1, originally from , ATLANTA TESTING & ENGINEERING, INC. 1991. CONSTANT-RATE DISCHARGE AQUIFER PUMPING TEST AND ANALYSIS FOR KIRLAND SOD FARM, VOLUSIA COUNTY, FLORIDA. CUP NO. 2-127-0236ANR. WINTER PARK, FLA.
Comments:TRANSMISSIVITY, STORATIVITY AND LEAKANCE FROM OBSERVATION WELL. ANALYTICAL METHOD: HANTUSH AND JACOB (1955) FLOW EQUATIONS

Page generated at: 20-SEP-2024 21:13 EDT