DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Villages VWCA IR-3
VWCAIR-3
342392
1643309
Start Test Date:
27-OCT-2003 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
413837
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
6
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
595
Storativity:
Tested Interval Max. (ft BLS):
890
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
Comments:
Step drawdown test Q=2,200 to 3,950 gpm
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Villages VWCA IR-3
VWCAIR-3
342392
1643309
Start Test Date:
02-JUL-2004 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
1733783
Discharge Rate (gal/min):
4000
Horizontal K (ft/day):
Hours Pumped:
336
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
595
Storativity:
.029
Tested Interval Max. (ft BLS):
890
Leakance (1/day):
.00025
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
Comments:
Step drawdown test Q=1,600 to 3,315 gpm