DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Fort Odgen, Lettuce Lake #1
W-12098
337494
996081
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
9091
Discharge Rate (gal/min):
Horizontal K (ft/day):
11.81
Hours Pumped:
26
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
270
Storativity:
.00036
Tested Interval Max. (ft BLS):
1000
Leakance (1/day):
.000036
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Geraghty and Miller, 1975(a)
Comments:
Zones above and below were also monitored as well as regional wells; barometric and tidal effects considered; a multi-zoned well drilled 200' from the production well yielded very small drawdown, possibly due to well construction or geologic structure.:Te
Page generated at: 04-OCT-2025 06:45 EDT