DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Fort Odgen, Lettuce Lake #1W-12098337494996081

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):9091
Discharge Rate (gal/min):Horizontal K (ft/day):11.81
Hours Pumped:26Vertical K (ft/day):
Tested Interval Min. (ft BLS):270Storativity:.00036
Tested Interval Max. (ft BLS):1000Leakance (1/day):.000036
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Geraghty and Miller, 1975(a)
Comments:Zones above and below were also monitored as well as regional wells; barometric and tidal effects considered; a multi-zoned well drilled 200' from the production well yielded very small drawdown, possibly due to well construction or geologic structure.:Te

Page generated at: 04-OCT-2025 06:45 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?