DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SW ST Pete Injection
W-13443
110408
1263019
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
1203209
Discharge Rate (gal/min):
Horizontal K (ft/day):
3252
Hours Pumped:
67
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
921
Storativity:
.0002
Tested Interval Max. (ft BLS):
1121
Leakance (1/day):
.0000071
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , CH2M Hill, 1982(a)
Comments:
Wells penetrate only the Avon Park Limestone which is non-potable in the area; monitored both the zones above and below; no corrections made; deep well injection site.:Tested Formation -AP
Page generated at: 04-OCT-2025 07:02 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?