DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SW ST Pete InjectionW-134431104081263019

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):1203209
Discharge Rate (gal/min):Horizontal K (ft/day):3252
Hours Pumped:67Vertical K (ft/day):
Tested Interval Min. (ft BLS):921Storativity:.0002
Tested Interval Max. (ft BLS):1121Leakance (1/day):.0000071
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , CH2M Hill, 1982(a)
Comments:Wells penetrate only the Avon Park Limestone which is non-potable in the area; monitored both the zones above and below; no corrections made; deep well injection site.:Tested Formation -AP

Page generated at: 04-OCT-2025 07:02 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?