DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ROYAL TEE GOLF COURSEW-15799319133836039

Start Test Date:01-JAN-1983 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):13904
Discharge Rate (gal/min):Horizontal K (ft/day):
Hours Pumped:216Vertical K (ft/day):
Tested Interval Min. (ft BLS):360Storativity:.00033
Tested Interval Max. (ft BLS):863Leakance (1/day):.000062
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, JANUARY 1991, CITY OF CAPE CORAL MASTER WATER SUPPLY PLAN-PHASE II
Comments:ESTIMATED TRANSMISSIVITY OF BASED ON COMBINED THICKNESSES OF BOTH AQUIFERS TRANSMISSIVITY OF LOWER HAWTHORN: 54000 GPD/FT TRANSMISSITY OF UPPER SUWANEE: 50000 GPD/FT ADDITIONAL INFORMATION: MISSIMER & ASSOC. JUNE, 1984

Page generated at: 29-JUN-2024 06:40 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?