DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROYAL TEE GOLF COURSE
W-15799
319133
836039
Start Test Date:
01-JAN-1983 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
13904
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
216
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
360
Storativity:
.00033
Tested Interval Max. (ft BLS):
863
Leakance (1/day):
.000062
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER, JANUARY 1991, CITY OF CAPE CORAL MASTER WATER SUPPLY PLAN-PHASE II
Comments:
ESTIMATED TRANSMISSIVITY OF BASED ON COMBINED THICKNESSES OF BOTH AQUIFERS TRANSMISSIVITY OF LOWER HAWTHORN: 54000 GPD/FT TRANSMISSITY OF UPPER SUWANEE: 50000 GPD/FT ADDITIONAL INFORMATION: MISSIMER & ASSOC. JUNE, 1984
Page generated at: 29-JUN-2024 06:40 EDT