DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
27.1
Discharge Rate (gal/min):
46.3
Horizontal K (ft/day):
.11
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
922
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
25.1
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.14
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
922
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
42.7
Discharge Rate (gal/min):
10.9
Horizontal K (ft/day):
.37
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
922
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0300
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
29
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.76
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
922
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0400
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
35.9
Discharge Rate (gal/min):
44.1
Horizontal K (ft/day):
.25
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
830
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0500
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
32.9
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.39
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
830
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0600
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
24.4
Discharge Rate (gal/min):
34.7
Horizontal K (ft/day):
.11
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
830
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0700
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
18.3
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.14
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
830
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0800
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
21.7
Discharge Rate (gal/min):
37.5
Horizontal K (ft/day):
.18
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
746
Storativity:
Tested Interval Max. (ft BLS):
776
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 0900
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
14.2
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.47
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
746
Storativity:
Tested Interval Max. (ft BLS):
776
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 1000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
60.6
Discharge Rate (gal/min):
10
Horizontal K (ft/day):
.12
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
776
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 1100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
27.1
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.15
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
776
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 1200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
65
Discharge Rate (gal/min):
55
Horizontal K (ft/day):
.19
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE UTILITIES WASTE WATER TREATMENT PLANT
W-15831
130492
1138003
Start Test Date:
25-DEC-2000 1300
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
57.7
Discharge Rate (gal/min):
0
Horizontal K (ft/day):
.27
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
745
Storativity:
Tested Interval Max. (ft BLS):
960
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1984, HYDROGEOLOGIC REPORT: DRILLING AND TESTING OF AN EXPLORATORY TEST WELL FOR DEEP INJECTION OF MUNICIPAL WASTEWATER AT THE SW WASTEWATER TREATMENT PLANT
Comments:
PARAMETERS DETERMINED FROM JACOB MODIFIED METHOD USING RECOVERY
Page generated at: 04-OCT-2025 05:11 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?