DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
WELLFIELD CLUSTER SITE B AT SANIBEL
W-15999
287770
771803
Start Test Date:
28-AUG-1985 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
6233
Discharge Rate (gal/min):
402
Horizontal K (ft/day):
Hours Pumped:
42.17
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
664
Storativity:
.000034
Tested Interval Max. (ft BLS):
770
Leakance (1/day):
.000016
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER AND ASSOCIATES, INC. 1985. HYDROGEOLOGIC INVESTIGATION OF THE HAWTHORN AND SUWANNEE AQUIFER SYSTEMS AT WELLFIELD CLUSTER SITE B. SANIBEL ISLAND, FLORIDA.
Comments:
LEAKANCE VALUE OF .000267/DAY WAS ALSO DETERMINED BUT MOST LIKELY CORRESPONDS TO THE LEAKANCE OF THE CONFINING BEDS BENEATH SUWANNEE-ZONE I - FROM HANTUSH-JACOB METHOD. THIS METHOD APPEARS TO BE THE MOST ACCURATE ANALYSIS BUT OTHER METHODS WERE USED - SEE ANALYSIS INFO.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
W-16000
285314
771622
HANTUSH-JACOB (1955)
194
6150
.000034
.000016
W-16000
285314
771622
JACOB STRAIGHT-LINE (1952)
194
6751
.005
Page generated at: 28-SEP-2024 21:30 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?