DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
WELLFIELD CLUSTER SITE B AT SANIBELW-16000285314771622

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):6759
Discharge Rate (gal/min):Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):740Storativity:.000034
Tested Interval Max. (ft BLS):770Leakance (1/day):.00014
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER, JANUARY 1991, CITY OF CAPE CORAL MASTER WATER SUPPLY PLAN-PHASE II
Comments:ESTIMATED TRANSMISSIVITY OF BASED ON COMBINED THICKNESSES OF BOTH AQUIFERS TRANSMISSIVITY OF LOWER HAWTHORN: 17000 GPD/FT TRANSMISSITY OF UPPER SUWANEE: 32880 GPD/FT

Page generated at: 04-OCT-2025 07:02 EDT