DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF BOYNTON BEACH UTIL DEPT- BOYNTON BCH WEST WTPW-16682943436798937

Start Test Date:06-JUN-1991 0713Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):66Horizontal K (ft/day):
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1737Storativity:
Tested Interval Max. (ft BLS):1759Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, JUNE 1992, DRILLING AND TESTING OF THE CONCENTRATE INJECTION AND DUAL MW-CITY OF BOYTON BEACH WEST WTP
Comments:PACKER TEST 1 0F 4 PACKER TESTS WERE RUN FOR WATER QUALITY AND FOR THE DESIGNATION OF USDW



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF BOYNTON BEACH UTIL DEPT- BOYNTON BCH WEST WTPW-16682943436798937

Start Test Date:07-JUN-1991 0345Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):83Horizontal K (ft/day):
Hours Pumped:4.8Vertical K (ft/day):
Tested Interval Min. (ft BLS):1708Storativity:
Tested Interval Max. (ft BLS):1729Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, JUNE 1992, DRILLING AND TESTING OF THE CONCENTRATE INJECTION AND DUAL MW-CITY OF BOYTON BEACH WEST WTP
Comments:PACKER TEST 2 OF 4 TESTS WERE RUN FOR WATER QUALITY AND TO DESIGNATE THE USDW



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF BOYNTON BEACH UTIL DEPT- BOYNTON BCH WEST WTPW-16682943436798937

Start Test Date:07-JUN-1991 2132Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):60Horizontal K (ft/day):
Hours Pumped:1.7Vertical K (ft/day):
Tested Interval Min. (ft BLS):1608Storativity:
Tested Interval Max. (ft BLS):1629Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, JUNE 1992, DRILLING AND TESTING OF THE CONCENTRATE INJECTION AND DUAL MW-CITY OF BOYTON BEACH WEST WTP
Comments:PACKER TEST 3 OF 4 TESTS WERE RUN FOR WATER QUALITY AND TO DESIGNATE THE USDW



SitePumped WellX-Coord(ft)Y-Coord (ft)
CITY OF BOYNTON BEACH UTIL DEPT- BOYNTON BCH WEST WTPW-16682943436798937

Start Test Date:08-JUN-1991 1300Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):75Horizontal K (ft/day):
Hours Pumped:3Vertical K (ft/day):
Tested Interval Min. (ft BLS):1428Storativity:
Tested Interval Max. (ft BLS):1449Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, JUNE 1992, DRILLING AND TESTING OF THE CONCENTRATE INJECTION AND DUAL MW-CITY OF BOYTON BEACH WEST WTP
Comments:PACKER TEST 4 OF 4 TESTS WERE RUN FOR WATER QUALITY AND TO DESIGNATE THE USDW

Page generated at: 04-OCT-2025 06:45 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?