DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
14-DEC-1993 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
4324
Discharge Rate (gal/min):
1065
Horizontal K (ft/day):
33.26
Hours Pumped:
36
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
390
Storativity:
Tested Interval Max. (ft BLS):
620
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP 22 UTOPIA, JANUARY 1995
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
13-APR-1994 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
APT
Transmissivity (ft2/day):
247000
Discharge Rate (gal/min):
3500
Horizontal K (ft/day):
433
Hours Pumped:
81
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
950
Storativity:
Tested Interval Max. (ft BLS):
1800
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP 22 UTOPIA, JANUARY 1995
Comments:
TESTED INTERVAL EXTENDS SEVERAL HUNDRED FEET INTO LOWER CONFINING UNIT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
19-APR-1994 0000
Aquifer:
INTERMEDIATE AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
310
Discharge Rate (gal/min):
25
Horizontal K (ft/day):
5.16
Hours Pumped:
50
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
230
Storativity:
Tested Interval Max. (ft BLS):
290
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP 22 UTOPIA, JANUARY 1995
Comments:
TEST CONDUCTED WITHIN THE LOWER IAS. HORIZONTAL K-VALUE WAS CALCULATED AND BASED ON THE RESULTS OF THE DRAWDOWN
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
25-DEC-2001 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
200535
Discharge Rate (gal/min):
Horizontal K (ft/day):
269.17
Hours Pumped:
81
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
940
Storativity:
.000012
Tested Interval Max. (ft BLS):
1685
Leakance (1/day):
.0063
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD-ROMP, Jan. 1995 to Aug. 1997.
Comments:
MONITORED SHALLOW ZONES; ANALYSIS METHODS: JACOB'S STRAIGHT-LINE FOR NON-STEADY STATE OF CONFINED AQUIFER.:TESTED FORMATION -AP
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.4
Discharge Rate (gal/min):
Horizontal K (ft/day):
.185
Hours Pumped:
.3
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
780
Storativity:
Tested Interval Max. (ft BLS):
834
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD-ROMP, Jan 1995
Comments:
T value represent a range of estimates from the analysis of 4 packer tests within the interval of 730' - 834' and from 840' - 937'; vertical hydraulic conductivity ranges from 0.04 to 0.33 ft/day in Oc1 and 0.14 - 1.16 in Oc2..:Tested Formation -Oc
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
25-DEC-2001 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
15
Discharge Rate (gal/min):
Horizontal K (ft/day):
.65
Hours Pumped:
.3
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
840
Storativity:
Tested Interval Max. (ft BLS):
937
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD-ROMP, Jan 1995
Comments:
T value represent a range of estimates from the analysis of 4 packer tests within the interval of 730' - 834' and from 840' - 937'; vertical hydraulic conductivity ranges from 0.04 to 0.33 ft/day in Oc1 and 0.14 - 1.16 in Oc2..:Tested Formation -Oc
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 22 Utopia
W-16783
219698
1082393
Start Test Date:
25-DEC-2002 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
Horizontal K (ft/day):
.036
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1705
Storativity:
Tested Interval Max. (ft BLS):
1795
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD-ROMP, Jan. 1995
Comments:
T value is an average estimate from the analysis of 2 packer tests within the interval of 1,705' - 1,795'; average vertical hydraulic conductivity is 0.036 ft/day.:Tested Formation -L- AP