DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
ROMP 33 WaterburyW-167842471921135195

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):3945
Discharge Rate (gal/min):Horizontal K (ft/day):11.4
Hours Pumped:40.5Vertical K (ft/day):
Tested Interval Min. (ft BLS):404Storativity:
Tested Interval Max. (ft BLS):750Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD-ROMP, 1994(d)
Comments:T was estimated to be 20,685 gpd/ft during recovery; analytical method used is Jacob's straight line.:Tested Formation -Tp-S

Page generated at: 04-OCT-2025 10:22 EDT