DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH MARTIN COUNTY WWTP- JENSEN BEACHW-169638961501057142

Start Test Date:13-FEB-1991 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):77723
Discharge Rate (gal/min):2060Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):1063Storativity:.0004
Tested Interval Max. (ft BLS):1289Leakance (1/day):.0055
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERAGHTY & MILLER, 1991, CONSTRUCTION AND TESTING OF FLORIDAN AQUIFER WELLS RO-1 AND RO-2 FOR THE NORTH MARTIN COUNTY WATER TREATMENT SYSTEM, JENSEN BEACH, FLORIDA
Comments:VALUES ARE AVERAGES OF HANTUSH (1956) & WALTON (1960) METHODS SUWANNEE LS, OCALA LS & UPPER AVON PARK FM.

Page generated at: 04-OCT-2025 05:28 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?