DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:02-MAR-1993 0840Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):7720
Discharge Rate (gal/min):400Horizontal K (ft/day):38
Hours Pumped:20Vertical K (ft/day):
Tested Interval Min. (ft BLS):40Storativity:
Tested Interval Max. (ft BLS):200Leakance (1/day):
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:FULLY PENETRATING; TRANSMISSIVITY HAD AVERAGED VALUES BETWEEN 6650 - 7720 FT2/DAY AND AVERAGED HYDRAULIC CONDUCTIVITY VALUES BETWEEN 35 - 38 FT/DAY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:27-FEB-1996 1146Aquifer:INTERMEDIATE AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):162
Discharge Rate (gal/min):37Horizontal K (ft/day):
Hours Pumped:35Vertical K (ft/day):
Tested Interval Min. (ft BLS):370Storativity:.0002
Tested Interval Max. (ft BLS):430Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:19-AUG-1996 0850Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):333
Discharge Rate (gal/min):150Horizontal K (ft/day):
Hours Pumped:83.5Vertical K (ft/day):
Tested Interval Min. (ft BLS):485Storativity:.00019
Tested Interval Max. (ft BLS):600Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL, JANUARY 1998
Comments:



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:25-FEB-1997 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:APTTransmissivity (ft2/day):59600
Discharge Rate (gal/min):3000Horizontal K (ft/day):
Hours Pumped:120Vertical K (ft/day):
Tested Interval Min. (ft BLS):960Storativity:
Tested Interval Max. (ft BLS):1642Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL, JANUARY 1998
Comments:LOWER PERMEABLE ZONE OF THE UPPER FLORIDAN-AVON PARK FORMATION



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:01-JUN-1994 1035Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):0.45Horizontal K (ft/day):.006
Hours Pumped:3.33Vertical K (ft/day):
Tested Interval Min. (ft BLS):2060Storativity:
Tested Interval Max. (ft BLS):2085Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:INTERVAL TESTED IN AVON PARK FORMATION



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:01-JUN-1994 1211Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):40Horizontal K (ft/day):20.7
Hours Pumped:3.5Vertical K (ft/day):
Tested Interval Min. (ft BLS):1855Storativity:
Tested Interval Max. (ft BLS):1920Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN AVON PARK FORMATION



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:21-JUN-1994 1005Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):6.7Horizontal K (ft/day):.125
Hours Pumped:3.6Vertical K (ft/day):
Tested Interval Min. (ft BLS):2030Storativity:
Tested Interval Max. (ft BLS):2085Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN AVON PARK FORMATION



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:10-AUG-1995 0920Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):4.2Horizontal K (ft/day):.019
Hours Pumped:2.2Vertical K (ft/day):
Tested Interval Min. (ft BLS):623Storativity:
Tested Interval Max. (ft BLS):725Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN UPPER OCALA LIMESTONE



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:10-AUG-1995 1552Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):2.4Horizontal K (ft/day):.016
Hours Pumped:2.25Vertical K (ft/day):
Tested Interval Min. (ft BLS):674Storativity:
Tested Interval Max. (ft BLS):725Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN THE UPPER OCALA LIMESTONE. DISCHARGE RATE IS AVERAGE AFTER DROPPING MAX AND MIN.



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:15-AUG-1995 0800Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):3.9Horizontal K (ft/day):.013
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):724Storativity:
Tested Interval Max. (ft BLS):825Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN UPPER OCALA LIMESTONE FORMATION



SitePumped WellX-Coord(ft)Y-Coord (ft)
SWFWMD ROMP 28 KUHLMANW-170005152341103531

Start Test Date:15-AUG-1995 1359Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):1.9Horizontal K (ft/day):.011
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):779Storativity:
Tested Interval Max. (ft BLS):825Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , SWFWMD DRILLING AND TESTING REPORT, ROMP 28 KUHLMAN, HIGHLANDS COUNTY, FL., JANUARY 1998
Comments:TESTED INTERVAL IN UPPER OCALA LIMESTONE FORMATION. DISCHARGE RATE AVERAGE AFTER DROPPING MAX AND MIN.

Page generated at: 04-OCT-2025 07:02 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?