DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 9 North Port
W-17001
541153
1023577
Start Test Date:
12-JUN-1995 0000
Aquifer:
SURFICIAL AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
16300
Discharge Rate (gal/min):
889
Horizontal K (ft/day):
57.7
Hours Pumped:
167.04
Vertical K (ft/day):
68.1
Tested Interval Min. (ft BLS):
30
Storativity:
.0016
Tested Interval Max. (ft BLS):
300
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP 14 HICORIA, FEBRUARY 1998
Comments:
DRAWDOWN MEASURED IN NUMEROUS SURFICIAL AQUIFER MONITOR WELLS. APT PARAMETERS REPRESENT THE AVERAGE OF THREE ANALYTICAL METHODS. THIS APT ENCOMPASSES THE LOWER PORTION OF THE ARCADIA FORMATION OF THE HAWTHORN GROUP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 14 Hicoria - Well No 1
W-17001
541153
1023577
Start Test Date:
07-FEB-1996 0000
Aquifer:
MID-HAWTHORN AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
31.2
Discharge Rate (gal/min):
14.65
Horizontal K (ft/day):
.529
Hours Pumped:
52.2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
460
Storativity:
.0025
Tested Interval Max. (ft BLS):
521
Leakance (1/day):
.000005
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP 14 HICORIA REPORT, FEBRUARY 1998.
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 14 Hicoria - Well No 1
W-17001
541153
1023577
Start Test Date:
09-SEP-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
7580
Discharge Rate (gal/min):
1651.19
Horizontal K (ft/day):
11.36
Hours Pumped:
118
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1003
Storativity:
.000022
Tested Interval Max. (ft BLS):
1670
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , SWFWMD ROMP, 1998
Comments:
APT PARAMETERS REPRESENT THE AVERAGE OF TWO ANALYTICAL METHODS. NO DRAWDOWN DATA COULD BE MADE USEFUL FOR CALCULATION OF PARAMETERS. HOWEVER, RECOVERY DATA WERE USED TO CALCULATE T AND S. LOW TRANSMISSIVITY MAY BE ATTRIBUTED IN PART TO WELL CONSTRUCTION. THIS TEST DID NOT PENETRATE THE MOST PERMEABLE SECTION OF THE AVON PARK.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ROMP 14 Hicoria - Well No 1
W-17001
541153
1023577
Start Test Date:
11-APR-1995 0000
Aquifer:
MIDDLE FAS CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
.22
Discharge Rate (gal/min):
0.47
Horizontal K (ft/day):
.0027
Hours Pumped:
2.0834
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1937
Storativity:
Tested Interval Max. (ft BLS):
1997
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , ROMP 14 HICORIA MONITOR WELL SITE, HIGHLANDS COUNTY, FINAL REPORT- DRILLING & TESTING PROGRAM, FEBRUARY 1998.
Comments:
Page generated at: 04-OCT-2025 05:11 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|