DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PAHOKEE INJECTION WELL SITE
W-17052
764971
896740
Start Test Date:
25-DEC-2000 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
10594
Discharge Rate (gal/min):
Horizontal K (ft/day):
232.44
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1776
Storativity:
Tested Interval Max. (ft BLS):
1821
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
DUNCAN, J.G., W.L. EVANS, III, J.G. AYLOR, AND L. LI. 1994. GEOLOGICAL FRAMEWORK OF THE LOWER FLORIDAN AQUIFER SYSTEM, ST. LUCIE, MARTIN AND PALM BEACH COUNTIES, FLORIDA. FGS.
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PAHOKEE INJECTION WELL SITE
W-17052
764971
896740
Start Test Date:
25-DEC-2000 0100
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
186.6
Discharge Rate (gal/min):
Horizontal K (ft/day):
9.07
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2350
Storativity:
Tested Interval Max. (ft BLS):
2370
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
DUNCAN, J.G., W.L. EVANS, III, J.G. AYLOR, AND L. LI. 1994. GEOLOGICAL FRAMEWORK OF THE LOWER FLORIDAN AQUIFER SYSTEM, ST. LUCIE, MARTIN AND PALM BEACH COUNTIES, FLORIDA. FGS.
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
PAHOKEE INJECTION WELL SITE
W-17052
764971
896740
Start Test Date:
11-OCT-1989 1625
Aquifer:
BOULDER ZONE
Test Type:
SPECIFIC CAPACITY
Transmissivity (ft2/day):
181707
Discharge Rate (gal/min):
1944
Horizontal K (ft/day):
Hours Pumped:
24
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2650
Storativity:
Tested Interval Max. (ft BLS):
3510
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY & MILLER, CONSTRUCTION AND TESTING OF INJECTION WELL SYSTEM #1: CITY OF PAHOKEE WASTEWATER TREATMENT PLANT. MARCH 1991.
Comments:
INJECTION TEST. T ESTIMATED FROM SPECIFIC CAPACITY, WHERE MAXIMUM PRESSURE BUILD-UP WAS 1.25 PSIG ~ 2.9 FEET OF WATER. SPECIFIC CAPACITY = 670 GPM/FT
Page generated at: 04-OCT-2025 10:24 EDT