DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
South Cross Bayou
W-17073
92615
1273197
Start Test Date:
03-OCT-1974 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
1203208
Discharge Rate (gal/min):
Horizontal K (ft/day):
3646
Hours Pumped:
34
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
953
Storativity:
.00022
Tested Interval Max. (ft BLS):
1072
Leakance (1/day):
.000018
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Hickey, 1979; 1982
Comments:
Well penetrate only the Avon Park Limestone which is non-potable in the area; monitored both the zone above and below; no corrections made; deep well injection site; analytical method used is Hantush-Jacob type curve.:Tested Formation -AP
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
South Cross Bayou
W-17073
92615
1273197
Start Test Date:
25-DEC-1974 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
2500
Discharge Rate (gal/min):
Horizontal K (ft/day):
9.6
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2000
Storativity:
Tested Interval Max. (ft BLS):
2260
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
HICKEY, 1979. HYDROGEOLOGY AND RESULTS OF INJECTION TESTS AT WASTE-INJECTION SITES IN PINELLAS COUNTY, FLORIDA. USGS WATER SUPPLY PAPER 2183
Comments:
Page generated at: 04-OCT-2025 05:11 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?