DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 142W-174805681991485912

Start Test Date:09-JUL-1996 0000Aquifer:LOWER FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):500000
Discharge Rate (gal/min):Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1098Storativity:
Tested Interval Max. (ft BLS):1409Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Data compiled in USGS WRIR 02-4036, data originally from, CH2M HILL
Comments:PUMP DATE = REFERENCE REPORT DATE; TRANSMISSIVITY > 500k



SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 142W-174805681991485912

Start Test Date:23-AUG-1996 1835Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):19.4
Discharge Rate (gal/min):Horizontal K (ft/day):.28
Hours Pumped:1Vertical K (ft/day):
Tested Interval Min. (ft BLS):2130Storativity:
Tested Interval Max. (ft BLS):2200Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
ST. JOHNS RIVER WMD SJRWMD SJ99-SP8
Comments:TRANSMISSIVITY ESTIMATED FROM RECOVERY TESTS. SPECIFIC CAPACITY = .5 G/M/FT INTERVAL 2



SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 142W-174805681991485912

Start Test Date:26-AUG-1996 1118Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):97.4
Discharge Rate (gal/min):Horizontal K (ft/day):1.39
Hours Pumped:5Vertical K (ft/day):
Tested Interval Min. (ft BLS):2016Storativity:
Tested Interval Max. (ft BLS):2086Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
ST. JOHNS RIVER WMD SJRWMD SP SJ99-SP8
Comments:TRANSMISSIVITY ESTIMATED FROM RECOVERY TESTS. AVG FROM 2 INTERVAL NUMBERS. SPECIFIC CAPACITY = 2.75 G/M/FT INTERVAL 3.



SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 142W-174805681991485912

Start Test Date:27-AUG-1996 1352Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):129
Discharge Rate (gal/min):Horizontal K (ft/day):1.84
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1945Storativity:
Tested Interval Max. (ft BLS):2015Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
ST. JOHNS RIVER WMD SJRWMD SP SJ99-SP8
Comments:TRANSMISSIVITY ESTIMATED FROM RECOVERY TESTS. SPECIFIC CAPACITY = 3.6 G/M/FT INTERVAL 4 PACKERS INFLATED DURING PUMPING PERIOD 1.



SitePumped WellX-Coord(ft)Y-Coord (ft)
USGS WRIR 02-4193 LFA APT AT 142W-174805681991485912

Start Test Date:28-AUG-1996 1642Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):8.13
Discharge Rate (gal/min):Horizontal K (ft/day):.12
Hours Pumped:4.75Vertical K (ft/day):
Tested Interval Min. (ft BLS):1722Storativity:
Tested Interval Max. (ft BLS):1792Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
ST. JOHNS RIVER WMD SJRWMD SP SJ99-SP8
Comments:TRANSMISSIVITY ESTIMATED FROM RECOVERY TESTS. AVG FROM 2 TEST PERIODS SPECIFIC CAPACITY = .175 G/M/FT INTERVAL 5. AVG PUMP RATE OF 10.7 G/MIN USED FOR RECOVERY ANALYSIS IN TEST PERIOD 1. AVG PUMP RATE OF 14.9 G/MIN USED FOR RECOVERY ANALYSIS IN TEST PERIOD 2.

Page generated at: 04-OCT-2025 10:33 EDT