DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
03-FEB-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
11.8
Discharge Rate (gal/min):
30
Horizontal K (ft/day):
36
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1812
Storativity:
Tested Interval Max. (ft BLS):
1844
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
STRADDLE PACKER TEST #1 K-VALUE WAS ASSUMED TO BE HORIZONTAL. SPECIFIC CAPACITY: 0.23 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
04-FEB-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.54
Discharge Rate (gal/min):
1
Horizontal K (ft/day):
.017
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1723
Storativity:
Tested Interval Max. (ft BLS):
1755
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
STRADDLE PACKER TEST #2 K-VALUE WAS ASSUMED TO BE HORIZONTAL. SPECIFIC CAPACITY: 0.01 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
06-FEB-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1.06
Discharge Rate (gal/min):
5
Horizontal K (ft/day):
.02
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1515
Storativity:
Tested Interval Max. (ft BLS):
1567
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
STRADDLE PACKER TEST #3 K-VALUE WAS ASSUMED TO BE HORIZONTAL. SPECIFIC CAPACITY: 0.03 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
07-FEB-1998 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
35.2
Discharge Rate (gal/min):
75
Horizontal K (ft/day):
.66
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1220
Storativity:
Tested Interval Max. (ft BLS):
1273
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
STRADDLE PACKER TEST #4 K-VALUE WAS ASSUMED TO BE HORIZONTAL SPECIFIC CAPACITY: 0.69 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
09-FEB-1998 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
.12
Discharge Rate (gal/min):
.75
Horizontal K (ft/day):
.01
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1389
Storativity:
Tested Interval Max. (ft BLS):
1400
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME APPENDICES A-K
32
Comments:
STADDLE PACKER TEST #5 K-VALUE WAS ASSUMED TO BE HORIZONTAL SPECIFIC CAPACITY: 0.004 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
01-APR-1998 0000
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2219
Storativity:
Tested Interval Max. (ft BLS):
2300
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
PACKER TEST #1 TRANSMISSIVITY AND HYDRAULIC CONDUCTIVITY NOT DETERMINED SPECIFIC CAPACITY: 9.43 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
03-APR-1998 0000
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2319
Storativity:
Tested Interval Max. (ft BLS):
3000
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
PACKER TEST #2 TRANSMISSIVITY AND HYDRAULIC CONDUCTIVITY WERE NOT DETERMINED SPECIFIC CAPACITY: 333.33 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
07-APR-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
89.4
Discharge Rate (gal/min):
85
Horizontal K (ft/day):
.57
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1794
Storativity:
Tested Interval Max. (ft BLS):
1950
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
JOHNSON ENGINEERING INC. & CH2MHILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
Comments:
PACKER TEST #3 K-VALUE WAS ASSUMED TO BE HORIZONTAL. SPECIFIC CAPACITY: 2.10 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
13-APR-1998 0000
Aquifer:
BOULDER ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
76
Discharge Rate (gal/min):
85
Horizontal K (ft/day):
.81
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1950
Storativity:
Tested Interval Max. (ft BLS):
2043
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
PACKER TEST #4 K-VALUE WAS ASSUMED TO BE HORIZONTAL SPECIFIC CAPACITY: 2.30 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FORT MYERS BEACH WWTP
W-17987
350744
785063
Start Test Date:
14-APR-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
178.9
Discharge Rate (gal/min):
85
Horizontal K (ft/day):
1.21
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1820
Storativity:
Tested Interval Max. (ft BLS):
1956
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, DECEMBER 1998, LEE COUNTY UTILITIES FT. MYERS BEACH WWTP DEEP INJECTION WELL ENGINEERING REPORT VOLUME 1 APPENDICES A-K
32
Comments:
PACKER TEST #5 K-VALUE WAS ASSUMED TO BE HORIZONTAL SPECIFIC CAPACITY: 2.02 GPM/FT
Page generated at: 04-OCT-2025 06:44 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?