SitePumped WellX-Coord(ft)Y-Coord (ft)
Waterford DevelopmentWATERFPW1978991019039

Start Test Date:10-MAR-1990 0000Aquifer:MID-HAWTHORN AQUIFER
Test Type:APTTransmissivity (ft2/day):8021
Discharge Rate (gal/min):800Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):197Storativity:.0008
Tested Interval Max. (ft BLS):320Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Versar, 1990.
Comments:BACKGROUND WATER LEVEL MONITORED PRIOR TO TEST; T VALUE IS AVG.; CONFINED BEDS' VERT. HYDRAULIC K = 1.1 GPD/FT2; USED WALTON'S & COOPER-JACOB'S METHODS USED FOR ANALYSIS.