Min.Depth(feet) |
Max.Depth(feet) |
Aquifer |
Aquifer Source |
Aquifer Source Reference |
CitationId |
0 |
40 |
SURFICIAL AQUIFER SYSTEM |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
40 |
500 |
INTERMEDIATE CONFINING UNIT |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
500 |
|
FLORIDAN AQUIFER SYSTEM |
CONSULTANT |
MWH, Three Oaks WWTP Drilling and Testing Report |
117
|
500 |
580 |
LOWER HAWTHORN PRODUCING ZONE |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
500 |
1915 |
UPPER FLORIDAN AQUIFER (UFA) |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
580 |
1700 |
MIDDLE FAS CONFINING UNIT -MC1 |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
1700 |
1915 |
AVON-PARK PERMEABLE ZONE |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
1915 |
2130 |
MIDDLE FAS CONFINING UNIT -MC2 |
CONSULTANT |
MWH, 2006: Three Oaks WWTP Injection Well Drilling & Testing Report |
117
|
2130 |
|
LOWER FLORIDAN AQUIFER SYSTEM |
CONSULTANT |
MWH, Three Oaks WWTP Drilling and Testing Report |
117
|
2130 |
|
BOULDER ZONE |
CONSULTANT |
MWH, Three Oaks WWTP Drilling and Testing Report |
117
|
Page generated at: 28-SEP-2024 21:23 EDT