Min.Depth(feet) |
Max.Depth(feet) |
Aquifer |
Aquifer Source |
Aquifer Source Reference |
CitationId |
0 |
50 |
WATER TABLE AQUIFER |
CONSULTANT |
CH2M Hill, Oct. 2004 |
41
|
50 |
90 |
TAMIAMI CONFINING UNIT |
CONSULTANT |
CH2M Hill, Oct. 2004 |
41
|
90 |
130 |
LOWER TAMIAMI AQUIFER |
CONSULTANT |
CH2M Hill, Oct. 2004 |
41
|
130 |
150 |
SANDSTONE-CLASTIC ZONE |
SOUTH FLORIDA WMD |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
130 |
150 |
SANDSTONE AQUIFER |
SOUTH FLORIDA WMD |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
150 |
210 |
MID-HAWTHORN CONFINING UNIT |
SOUTH FLORIDA WMD |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
150 |
150 |
SANDSTONE-CARBONATE ZONE |
SOUTH FLORIDA WMD |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
210 |
320 |
MID-HAWTHORN AQUIFER |
SOUTH FLORIDA WMD |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
320 |
560 |
LOWER HAWTHORN CONFINING UNIT |
CONSULTANT |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
320 |
560 |
INTERMEDIATE CONFINING UNIT |
CONSULTANT |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
560 |
960 |
INTERMEDIATE AQUIFER SYSTEM |
CONSULTANT |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
960 |
1080 |
UPPER FLORIDAN AQUIFER (UFA) |
CONSULTANT |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
1080 |
|
MIDDLE FAS CONFINING UNIT -MC1 |
CONSULTANT |
CH2M Hill, Oct. 2004 |
41
|
1930 |
2380 |
LOWER FLORIDAN AQUIFER SYSTEM |
CONSULTANT |
CH2M HILL. 2004: Engineering Report on Bonita Springs WRF Deep Injection System |
41
|
2380 |
|
BOULDER ZONE |
CONSULTANT |
CH2M Hill, Oct. 2004 |
41
|
Page generated at: 04-OCT-2025 10:12 EDT