DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BIG CYPRESS FLORIDAN TEST SITE
BICY-PW
554523
567149
Start Test Date:
13-APR-1998 0000
Aquifer:
INTERMEDIATE AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
68022
Discharge Rate (gal/min):
2700
Horizontal K (ft/day):
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
465
Storativity:
.000068
Tested Interval Max. (ft BLS):
550
Leakance (1/day):
.002
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., February 2004, Hydrogeologic Investigation of the Floridan Aquifer System Big Cypress Preserve Collier County, Florida Technical Publication WS-18.
13
Comments:
BASED ON THE MOENCH ANALYTICAL MODEL. Obs well = BICY-MZ1 (BICY-TW)
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BIG CYPRESS FLORIDAN TEST SITE
BICY-PW
554523
567149
Start Test Date:
14-JUL-1998 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
11209
Discharge Rate (gal/min):
820
Horizontal K (ft/day):
Hours Pumped:
50
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
840
Storativity:
.000005
Tested Interval Max. (ft BLS):
1010
Leakance (1/day):
.000086
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
Bennett, Michael W., P.G., February 2004, Hydrogeologic Investigation of the Floridan Aquifer System Big Cypress Preserve Collier County, Florida Technical Publication WS-18.
13
Comments:
LEAKANCE WAS FOUND TO BE EVENLY DISTRIBUTED BETWEEN THE UPPER AND LOWER CONFININING UNITS. T & S VALUES CALCULATED USING THE MOENCH SOLUTION.
Page generated at: 29-SEP-2024 01:29 EDT