DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Cypress Lake Wellfield - Toho Water AuthorityCL_UFTPW5622801367162

Start Test Date:16-OCT-2007 1000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):52524
Discharge Rate (gal/min):1900Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):185.89Storativity:.0006
Tested Interval Max. (ft BLS):533.89Leakance (1/day):.00002
No. Monitored Wells:8Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT ARDAMAN & ASSOCIATES, INC., JAN 2008, "APT PERFORMANCE TEST RESULTS OF UPPER FLORIDAN TEST/PRODUCTION WELL CYPRESS LAKE WELLFIELD"
Comments:RECOMMENDED PARAMETERS OF AVERAGES GIVEN IN REPORT REFERENCED ABOVE. TRANSMISSIVITY RANGED BETWEEN 48,375 AND 56,674; STORATIVITY RANGED BETWEEN .0003 AND .0009; LEAKANCE RANGED BETWEEN .000003 AND .000038

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
CL_UFMW1
562268
1367044
HANTUSH-JACOB (1955)
119
50000
.0003
.0024

Page generated at: 29-SEP-2024 01:22 EDT