DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
East Lake Road Wellfield Well EL-19
EL-19
116427
1375787
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
47193
Discharge Rate (gal/min):
Horizontal K (ft/day):
235.96
Hours Pumped:
120
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
250
Storativity:
.00019
Tested Interval Max. (ft BLS):
450
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Nettles and Vandor, 1989.
Comments:
Regional water level fluctuations and barometric pressure changes were monitored prior to test; adjustment was applied to potentiometric surface due pre-pumping rainfall conditions; analytical method used are Hantush-Jacob's leaky artesian aquifer, Jacob'