DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELLLAGORCECC943096547439

Start Test Date:25-DEC-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):4193
Discharge Rate (gal/min):986.5Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):915Storativity:
Tested Interval Max. (ft BLS):1206Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 35.65 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.



SitePumped WellX-Coord(ft)Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELLLAGORCECC943096547439

Start Test Date:25-DEC-2001 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):12395
Discharge Rate (gal/min):1907.5Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):915Storativity:
Tested Interval Max. (ft BLS):1206Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 28.15 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.



SitePumped WellX-Coord(ft)Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELLLAGORCECC943096547439

Start Test Date:25-DEC-2001 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):12179
Discharge Rate (gal/min):2598.3Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):915Storativity:
Tested Interval Max. (ft BLS):1206Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 32.05 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.

Page generated at: 29-SEP-2024 01:30 EDT