DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL
LAGORCECC
943096
547439
Start Test Date:
25-DEC-2001 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
4193
Discharge Rate (gal/min):
986.5
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
915
Storativity:
Tested Interval Max. (ft BLS):
1206
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:
SPECIFIC CAPACITY = 35.65 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL
LAGORCECC
943096
547439
Start Test Date:
25-DEC-2001 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
12395
Discharge Rate (gal/min):
1907.5
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
915
Storativity:
Tested Interval Max. (ft BLS):
1206
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:
SPECIFIC CAPACITY = 28.15 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
L GORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL
LAGORCECC
943096
547439
Start Test Date:
25-DEC-2001 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
12179
Discharge Rate (gal/min):
2598.3
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
915
Storativity:
Tested Interval Max. (ft BLS):
1206
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERHARDT M. WITT. 2002. LAGORCE COUNTRY CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:
SPECIFIC CAPACITY = 32.05 GPM/FT AT 60 MIN. TRANSMISSIVITY DETERMINED BY COOPER-JACOB ANALYSIS METHOD USING SPECIFIC CAPACITY VALUE.
Page generated at: 29-SEP-2024 01:30 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?