DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
FAS TEST WELLS AT S65A STRUCTUREOSF-1056131251208515

Start Test Date:28-SEP-2006 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):11424
Discharge Rate (gal/min):1950Horizontal K (ft/day):
Hours Pumped:69.25Vertical K (ft/day):
Tested Interval Min. (ft BLS):330Storativity:.0055
Tested Interval Max. (ft BLS):550Leakance (1/day):.21
No. Monitored Wells:7Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT BENNETT, M. HYDROGEOLOGIC INVESTIGATION OF THE FAS S-65A SITE, OSCEOLA COUNTY FLORIDA (OSF-104 &OSF-105). AECOM WATER. NOVEMBER, 2008.
Comments:



SitePumped WellX-Coord(ft)Y-Coord (ft)
FAS TEST WELLS AT S65A STRUCTUREOSF-1056131251208515

Start Test Date:22-JAN-2007 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:APTTransmissivity (ft2/day):78877
Discharge Rate (gal/min):2795Horizontal K (ft/day):
Hours Pumped:95Vertical K (ft/day):
Tested Interval Min. (ft BLS):930Storativity:
Tested Interval Max. (ft BLS):1202Leakance (1/day):
No. Monitored Wells:7Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT BENNETT, M. HYDROGEOLOGIC INVESTIGATION OF THE FAS S-65A SITE, OSCEOLA COUNTY FLORIDA (OSF-104 &OSF-105). AECOM WATER. NOVEMBER, 2008.
Comments:THIS TEST WAS CONDUCTED IN A HIGHLY FRACTURED INTERVAL. THE MAXIIMUM AVAILABLE PUMPING RATE WAS INADEQUATE TO PRODUCE SIGNIFICANT DRAWDOWN IN THE PRODUCTION ZONE MONITOR WELL, AND THE RECOVERY DATA FROM THE PRODUCTION WELL WAS OSCILLATORY AND NEAR INSTANTANEOUS, PREVENTING MEANINGFUL INTERPRETATION. REPORTED TRANSMISSIVITYIS A ROUGH ESTIMATE BASED ON SPECIFIC CAPACITY, IT IS BELIEVED TO BE A SIGNIFICANT UNDERESTIMATE.

Page generated at: 29-SEP-2024 00:22 EDT