DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2
PBF-9
748908
860075
Start Test Date:
03-APR-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
9634
Discharge Rate (gal/min):
1550
Horizontal K (ft/day):
39
Hours Pumped:
55
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1202
Storativity:
.00029
Tested Interval Max. (ft BLS):
1447
Leakance (1/day):
.00064
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL
82
Comments:
TWO MONITOR WELLS, ONE IN UPPER THE OTHER IN LOWER FLORIDAN FLOW ZONES. PBF-7 WAS PUMPING WELL FOR 2 APT'S. FIRST DRILLED AND PUMPED IN UPPER FLORIDAN FLOW ZONE THEN DRILLED DOWN TO LOWER FLORIDAN, COMPLETED AND PUMPED FOR APT2. THUS THE SAME PRODUCTION WELL (PBF-7) FOR BOTH APTS 1 AND 2.
View Water Quality Results for the Above Test
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
PBF-9
748908
860075
HANTUSH-JACOB (1955)
398
12.2
9505
.00029
.00064
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2
PBF-9
748908
860075
Start Test Date:
14-MAY-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
68306
Discharge Rate (gal/min):
1030
Horizontal K (ft/day):
842
Hours Pumped:
69
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1960
Storativity:
.000026
Tested Interval Max. (ft BLS):
2040
Leakance (1/day):
.0043
No. Monitored Wells:
2
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL
82
Comments:
DUAL ZONE PUMPING WELL PBF-9 USED AS PRODUCTION WELL HERE. FINAL COMPLETION OF PBF-9 LEFT AS STATED HERE AND USED AS MONITOR WELL WITH DATALOGGER.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
PBF-9
748908
860075
THEIS RECOVERY
398
1.1
67393
.000026
.0043
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2
PBF-9
748908
860075
Start Test Date:
19-FEB-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
752.8
Discharge Rate (gal/min):
94
Horizontal K (ft/day):
6.5
Hours Pumped:
6
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
775
Storativity:
Tested Interval Max. (ft BLS):
890
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL
82
Comments:
PACKER TEST 5 OF 5 CONDUCTED IN PBF-9 NOT PBF-7. THIS WAS CONDUCTED WITH A MUD FILLED HOLE PRIOR TO SETTING CASING THROUGH HAWTHORN GROUP. THIS UPPER FLORIDAN ZONE DID NOT FLOW WHILE DRILLING REVERSE AIR THROUGH IT OVER IN PBF-7. ALL EVIDENCE POINTS TOWARD LOW PRODUCTIVITY.
View Water Quality Results for the Above Test
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
PBF-9
748908
860075
COOPER-JACOB APPROXIMATION
0
79
742.8
Page generated at: 22-NOV-2024 20:57 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?