DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2PBF-9748908860075

Start Test Date:03-APR-1997 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):9634
Discharge Rate (gal/min):1550Horizontal K (ft/day):39
Hours Pumped:55Vertical K (ft/day):
Tested Interval Min. (ft BLS):1202Storativity:.00029
Tested Interval Max. (ft BLS):1447Leakance (1/day):.00064
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL82
Comments:TWO MONITOR WELLS, ONE IN UPPER THE OTHER IN LOWER FLORIDAN FLOW ZONES. PBF-7 WAS PUMPING WELL FOR 2 APT'S. FIRST DRILLED AND PUMPED IN UPPER FLORIDAN FLOW ZONE THEN DRILLED DOWN TO LOWER FLORIDAN, COMPLETED AND PUMPED FOR APT2. THUS THE SAME PRODUCTION WELL (PBF-7) FOR BOTH APTS 1 AND 2.

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
PBF-9
748908
860075
HANTUSH-JACOB (1955)
398
12.2
9505
.00029
.00064



SitePumped WellX-Coord(ft)Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2PBF-9748908860075

Start Test Date:14-MAY-1997 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):68306
Discharge Rate (gal/min):1030Horizontal K (ft/day):842
Hours Pumped:69Vertical K (ft/day):
Tested Interval Min. (ft BLS):1960Storativity:.000026
Tested Interval Max. (ft BLS):2040Leakance (1/day):.0043
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL82
Comments:DUAL ZONE PUMPING WELL PBF-9 USED AS PRODUCTION WELL HERE. FINAL COMPLETION OF PBF-9 LEFT AS STATED HERE AND USED AS MONITOR WELL WITH DATALOGGER.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
PBF-9
748908
860075
THEIS RECOVERY
398
1.1
67393
.000026
.0043



SitePumped WellX-Coord(ft)Y-Coord (ft)
SOUTH BAY - FLORIDAN AQUIFER WELLS AT S-2PBF-9748908860075

Start Test Date:19-FEB-1997 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):752.8
Discharge Rate (gal/min):94Horizontal K (ft/day):6.5
Hours Pumped:6Vertical K (ft/day):
Tested Interval Min. (ft BLS):775Storativity:
Tested Interval Max. (ft BLS):890Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD DISTRICT TECHNICAL PUBLICATION WS-2, LUKASIEWICZ ET AL82
Comments:PACKER TEST 5 OF 5 CONDUCTED IN PBF-9 NOT PBF-7. THIS WAS CONDUCTED WITH A MUD FILLED HOLE PRIOR TO SETTING CASING THROUGH HAWTHORN GROUP. THIS UPPER FLORIDAN ZONE DID NOT FLOW WHILE DRILLING REVERSE AIR THROUGH IT OVER IN PBF-7. ALL EVIDENCE POINTS TOWARD LOW PRODUCTIVITY.

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
PBF-9
748908
860075
COOPER-JACOB APPROXIMATION
0
79
742.8

Page generated at: 22-NOV-2024 20:57 EDT