DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Kissimmee Basin Lower Floridan Aquifer Reconnaisance: Site BPOF-275359201324481

Start Test Date:16-JUN-2011 1453Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):15Horizontal K (ft/day):.67
Hours Pumped:1.43Vertical K (ft/day):
Tested Interval Min. (ft BLS):1360Storativity:
Tested Interval Max. (ft BLS):1375Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECHNICAL PUBLICATION WS-33216
Comments:K CALCULATION REFERENCE: CEDEGREN, HARRY R., SEEPAGE, DRAINAGE & FLOW-NETS. WILEY & SONS., 1977. P64. STATIC HEAD THIS INTERVAL = 51.31 FT NGVD

View Water Quality Results for the Above Test





SitePumped WellX-Coord(ft)Y-Coord (ft)
Kissimmee Basin Lower Floridan Aquifer Reconnaisance: Site BPOF-275359201324481

Start Test Date:17-JUN-2011 1230Aquifer:MIDDLE FAS CONFINING UNIT
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):40Horizontal K (ft/day):3.1
Hours Pumped:2.42Vertical K (ft/day):
Tested Interval Min. (ft BLS):1260Storativity:
Tested Interval Max. (ft BLS):1275Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECHNICAL PUBLICATION WS-33216
Comments:STATIC WATER-LEVEL AFTER RECOVER = 51.25

View Water Quality Results for the Above Test