DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BUDWF BUD-4 (Saddie Park)
SADDIEBUD4
243864
1314865
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
569519
Discharge Rate (gal/min):
Horizontal K (ft/day):
2027
Hours Pumped:
17
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
119
Storativity:
.045
Tested Interval Max. (ft BLS):
400
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Terra Environmental Services, Inc., 1998
Comments:
APT transmissivity and storativity calculations represent the average of two analytical methods. Short duration test. No leakance value. No data correction for regional trends.:Tested Formation -Tp-S
Page generated at: 05-JUL-2024 19:23 EDT