DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
10-APR-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
104.9
Discharge Rate (gal/min):
32.4
Horizontal K (ft/day):
35.2
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1185
Storativity:
.0001
Tested Interval Max. (ft BLS):
1207
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 3.45 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
10-APR-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
116.9
Discharge Rate (gal/min):
90
Horizontal K (ft/day):
39.2
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1185
Storativity:
.0001
Tested Interval Max. (ft BLS):
1207
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 3.82 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
10-APR-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
118.6
Discharge Rate (gal/min):
105
Horizontal K (ft/day):
39.8
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1185
Storativity:
.0001
Tested Interval Max. (ft BLS):
1207
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 3.87 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
25-APR-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.18
Discharge Rate (gal/min):
1.3
Horizontal K (ft/day):
.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1603
Storativity:
.0001
Tested Interval Max. (ft BLS):
1620
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.009 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
25-APR-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.28
Discharge Rate (gal/min):
3
Horizontal K (ft/day):
.12
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1603
Storativity:
.0001
Tested Interval Max. (ft BLS):
1620
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.014 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
29-APR-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1.17
Discharge Rate (gal/min):
4
Horizontal K (ft/day):
.41
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1739
Storativity:
.0001
Tested Interval Max. (ft BLS):
1760
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.05 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
29-APR-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.48
Discharge Rate (gal/min):
8.3
Horizontal K (ft/day):
.87
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1739
Storativity:
.0001
Tested Interval Max. (ft BLS):
1760
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.10 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
29-APR-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
4.13
Discharge Rate (gal/min):
10.7
Horizontal K (ft/day):
1.45
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1739
Storativity:
.0001
Tested Interval Max. (ft BLS):
1760
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.16 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
02-MAY-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.25
Discharge Rate (gal/min):
1.5
Horizontal K (ft/day):
.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1895
Storativity:
.0001
Tested Interval Max. (ft BLS):
1918
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = .012 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
02-MAY-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.25
Discharge Rate (gal/min):
1.8
Horizontal K (ft/day):
.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1895
Storativity:
.0001
Tested Interval Max. (ft BLS):
1918
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.012 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
02-MAY-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.25
Discharge Rate (gal/min):
2.5
Horizontal K (ft/day):
.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1895
Storativity:
.0001
Tested Interval Max. (ft BLS):
1918
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.012 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-MAY-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.73
Discharge Rate (gal/min):
2
Horizontal K (ft/day):
.27
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2100
Storativity:
.0001
Tested Interval Max. (ft BLS):
2120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.038 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-MAY-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.84
Discharge Rate (gal/min):
6
Horizontal K (ft/day):
.31
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2100
Storativity:
.0001
Tested Interval Max. (ft BLS):
2120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.039 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-MAY-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.73
Discharge Rate (gal/min):
8
Horizontal K (ft/day):
.27
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2100
Storativity:
.0001
Tested Interval Max. (ft BLS):
2120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.037 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
13-MAY-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.21
Discharge Rate (gal/min):
1.25
Horizontal K (ft/day):
.07
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2298
Storativity:
.0001
Tested Interval Max. (ft BLS):
2320
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.011 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
13-MAY-1996 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.63
Discharge Rate (gal/min):
5
Horizontal K (ft/day):
.21
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2298
Storativity:
.0001
Tested Interval Max. (ft BLS):
2320
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.032 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
13-MAY-1996 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.72
Discharge Rate (gal/min):
7
Horizontal K (ft/day):
.24
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2298
Storativity:
.0001
Tested Interval Max. (ft BLS):
2320
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 0.037 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-APR-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
140.2
Discharge Rate (gal/min):
33
Horizontal K (ft/day):
43.1
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1030
Storativity:
.0001
Tested Interval Max. (ft BLS):
1054
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 4.25 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-APR-1998 0100
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
118
Discharge Rate (gal/min):
30
Horizontal K (ft/day):
36.3
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1030
Storativity:
.0001
Tested Interval Max. (ft BLS):
1054
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 4.08 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-APR-1998 0200
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
128.5
Discharge Rate (gal/min):
60
Horizontal K (ft/day):
39.5
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1030
Storativity:
.0001
Tested Interval Max. (ft BLS):
1054
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 4.41 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
SO. COLLIER COUNTY WASTE WATER TREATMENT PLANT - FAS
SCRWWTPIW1
418933
641113
Start Test Date:
08-APR-1998 0300
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
128.5
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
39.5
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1030
Storativity:
.0001
Tested Interval Max. (ft BLS):
1054
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MISSIMER INTERNATIONAL, INC. 1997. COLLIER COUNTY SOUTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT INJECTION WELL IW-1 COMPLETION REPORT, VOLUME 1 - TEXT.
Comments:
SPECIFIC CAPACITY = 3.88 GPM/FT
Page generated at: 28-SEP-2024 23:39 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?