DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ST LUCIE NUCLEAR POWER PLANT
SLNPP-PW
901690
1096533
Start Test Date:
05-MAY-2006 0000
Aquifer:
SURFICIAL AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
6000
Discharge Rate (gal/min):
300
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
20
Storativity:
.002
Tested Interval Max. (ft BLS):
60
Leakance (1/day):
No. Monitored Wells:
12
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GZA GEOENVIRONMENTAL CORP., 2006, EVALUATION OF GROUNDWATER PUMPING TEST DATA INDEPENDENT SPENT FUEL STORAGE INSTALLATION ST LUCIE NUCLEAR POWER PLANT
Comments:
DRAWDOWN ANALYSIS: COOPER-JACOBS METHODS VIA AQTESOLVE SOFTWARE
Page generated at: 28-SEP-2024 23:34 EDT