DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Southwest St. Pete Well A3SSTPETE_B81051301232175

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):290107
Discharge Rate (gal/min):Horizontal K (ft/day):1934
Hours Pumped:84Vertical K (ft/day):
Tested Interval Min. (ft BLS):250Storativity:.0004
Tested Interval Max. (ft BLS):400Leakance (1/day):.00039
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Hickey and Spechler, 1979; Hickey, 1982.
Comments:T value was obtained from analysis of OB well; Hantush-Jacob type curve method was used the analysis; analysis of pumped well data from 6 to 270 min. using Jacob's semi-log straight-line method confirm T value; S value of 7.7 x 10-4 was also estimated fro

Page generated at: 29-SEP-2024 01:18 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?