DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
WELLFIELD CLUSTER SITE B AT SANIBELW-15999287770771803

Start Test Date:28-AUG-1985 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):6233
Discharge Rate (gal/min):402Horizontal K (ft/day):
Hours Pumped:42.17Vertical K (ft/day):
Tested Interval Min. (ft BLS):664Storativity:.000034
Tested Interval Max. (ft BLS):770Leakance (1/day):.000016
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER AND ASSOCIATES, INC. 1985. HYDROGEOLOGIC INVESTIGATION OF THE HAWTHORN AND SUWANNEE AQUIFER SYSTEMS AT WELLFIELD CLUSTER SITE B. SANIBEL ISLAND, FLORIDA.
Comments:LEAKANCE VALUE OF .000267/DAY WAS ALSO DETERMINED BUT MOST LIKELY CORRESPONDS TO THE LEAKANCE OF THE CONFINING BEDS BENEATH SUWANNEE-ZONE I - FROM HANTUSH-JACOB METHOD. THIS METHOD APPEARS TO BE THE MOST ACCURATE ANALYSIS BUT OTHER METHODS WERE USED - SEE ANALYSIS INFO.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
W-16000
285314
771622
HANTUSH-JACOB (1955)
194
6150
.000034
.000016
W-16000
285314
771622
JACOB STRAIGHT-LINE (1952)
194
6751
.005

Page generated at: 29-SEP-2024 01:24 EDT