DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
AMOCO B P (SUNBILL), 3591 W SUNRISE BLVD, FORT LAUDERDALE, 33311, data compiled by: Broward County Environmental Protection DepartmentBEPD-259919811656072

Start Test Date:11-NOV-1990 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:SLUGTransmissivity (ft2/day):2305
Discharge Rate (gal/min):Horizontal K (ft/day):22
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):7Storativity:
Tested Interval Max. (ft BLS):17Leakance (1/day):
No. Monitored Wells:6Specific Capacity (gpm/ft):
SourceReferenceCitation Id
FLORIDA DEPT OF ENV PROTECTION FDEP OCULUS files compiled by Broward County Environmental Protection Department
Comments:Average K of 6 Slug Tests used to calculate T., the report date was used as the aquifer test date.

Page generated at: 04-NOV-2024 16:06 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?